Wednesday, 11 April 2012

OBIEE services FORCE-SHUTTING-DOWN

Sometimes when you install OBIEE 11g with the help of Administrator and then restart the services then the services shows information of FORCED_SHUTDOWN.

This happened to me because in the below location the username and password was different.

\user_projects\domains\bifoundation_domain\servers\AdminServer\security

Try giving the username and password which is used while installing the RCU. But first check if the username and password is correct or not.

cwallet file will be present in the below mentioned paths.  Try opening the files, if you don't have the permissions of Administrator then you will get the 'Access Denied'error pop up.  So, ask your administrator to give you the permisssion and restart the services.

\instances\instance1\config\OPMN\opmn\wallet
\instances\instance1\config\JPS
\Oracle_BI1\products\Essbase\EssbaseServer\bin\wallet
\Oracle_BI1\sysman\config\monwallet

No comments:

Post a Comment

Thanks to Comment
--Add--